IN-BAE7 Medical Devices HIV Testing CD4 Cell Counter Flow Cytometry Machine

Place of Origin:
Guangdong, China
Brand Name:
ICEN
Power Source:
Electric
Warranty:
1 Year, 12 Months
After-sale Service:
Online technical support
Material:
metal
Description
IN-BAE7 Medical Devices HIV Testing CD4 Cell Counter Flow Cytometry Machine
t
Flow cytometry (FCM) is a technique used to detect and measure physical and chemical characteristics of a population of cells or particles. In this process, a sample containing cells or particles is suspended in a fluid and injected into the flow cytometer instrument. The sample is focused to ideally flow one cell at a time through a laser beam, where the light scattered is characteristic to the cells and their components. Cells are often labeled with fluorescent markers so light is absorbed and then emitted in a band of wavelengths. Tens of thousands of cells can be quickly examined and the data gathered are processed by a computer.
Clinical Application:
1. Analysis and absolute count of lymphocyte subsets:T/B/NK; 
2.Detection: ankylosing spondylitis;
3. Blood disease/lymphoma immunophenotyping; 
4. Functional lymphocyte subsets analysis: Th1, Treg;
5. Count of CD34 hemopoietic stem cell; 
6. PNH auxiliary diagnosis:CD55 , CD59 , FLARE,CD14 , CD15;
7. Multiple myeloma; 
8. Platelets: count and immunophenotype analysis of platelets;
9. Count of Reticulocytes; 
10. Minor residual disease monitor of acute leukemia; 
11. DNA ploidy analysis; 
Item Parameters
Laser 488nm solid
Detector FSC,SSC,FL1-FL5
 
Fluorescence Channel
FL1:525/50(FITC)                  FL2:585/40(PE)
FL3:630/30(PE-Texas Red/ECD/PI)     FL4:697/60(PerCP/PE-Cy5/PE-Cy5.5)
FL5:780/60(PE-Cy7)
Fluorescence sensitivity FITC ≤ 100 MESF;PE ≤ 50 MESF
Fluorescence linearity ≥ 0.99
FSC sensitivity ≤ 1μm
Test particle size 0.5-50μm
Carry Over ≤ 0.5%
Instrument CV FSC and all FL channel CV less than 2%
FSC and SSC CV Can separate red blood cells and platelet, can separate white blood cells into 3 groups
Test speed 38000 cells/s
Minimum Sample Vol 90μL
Measure Range Maximum Support 107
Threshold Double thresholdminimum cells fraction
Fluorescence compensation Support auto online compensation, offline compensation and visualized compensation
Item Template Support Item templateacquisition condition/ fluorescence compensation 1-click use
Intake method Manual intake
Rotary Wheel auto-sampling with auto- mixing function:32tests/wheel,
Liquid storage station sheath bottle, waste bottle, shutdown liquid bottle 2L     
cleaning liquid bottle 0.5L
Software English/Chinese
PC Dell(CPU i5/8G DDR4/1T hard disk)+Dell 27 inches monitor
Size/ Weight 500mm*605mm*305mm(L*W*H),35KG