IN-MS100 Ambulance Spo2 Sensor Pediatric Mobile Medical Simulator Bracket Patient Monitor

MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the
oximeter by simulation means, and gives cognizance of veracity about the oximeter.Because the oximeter manufacturer may use different R
Description

IN-MS100 Spo2 Simulator

Features
Separated connection between simulator probe and host, operation and test are more convenient.
262K color and 320*240 TFT, adjustable brightness level.
Film key-press, makes the operation more comfortable.
Power with chargeable lithium battery, can display the charge information of battery.
Key volume, can open or close.

Main Functions
oxygen saturation simulation;
Pulse rate simulation;
Patient state simulation preset;
Can test the reaction time of device;
Can simulate the SpO2 and pulse rate under different amplitude;
Can test the performance of device under different interference source;
Can select different R-curve.


Product parameters

SpO2
Measuring range: 35%~100%
Resolution:1%
Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when
SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
Pulse rate
Measuring range:25bpm~250bpm
Resolution:5bpm
Error:1%±1bpm
Amplitude
Measuring range:0.000%~20.000%
Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
Patient state
24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
Voltage
DC 3.6V~4.2V
Power Supply
Voltage 3.7 rechargeable lithium battery × 1
Battery working life
Charge and discharge no less than 500 times.
Accessaries

Measuring range : 35%~100%
Resolution :                                 1%
Error : When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is
74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
Measuring range : 25bpm~250bpm
Resolution : 5bpm
Error : 1%±1bpm
Measuring range : 0.000%~20.000%
Resolution : 1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
Voltage : DC 3.6V~4.2V

Company Profile

Our company is a leading exporter and supply chain service provider of medical machine with more than 8 years' experience.Our main products include X-ray machine, B ultrasound scanners, ECG, patient monitor, ICU equipment, Lab equipment, and other related medical disposables. We have exported products to more than 50 countries and built long term partnerships with clients.Your satisfaction is our duty! It will be our great honor to serve you. We do hope we can offer you more help in medical field and build the long term business relationship with you.

t